ADDRESSES 412-475: CUSTOM LCD ZONE DESCRIPTORS
Four of the descriptors that can be assigned to each zone (see Address 000) can be customized to suit a
specific installation. A total of sixteen characters, including spaces, can be entered for each LCD custom
zone descriptor using the following table. Each custom zone descriptor is entered in a series of
consecutive addresses. It is recommended to fill in all 16 characters for each custom zone descriptor.
Example: To set Custom Zone Descriptor 1 as “ABC”, enter 41, 42, 43, 20, 20, 20, 20, 20, 20, 20, 20,
20, 20, 20, 20, 20 at addresses 412-427, respectively.
20 space 2D
-
41
A
4E
N
61
A
6E
n
21 ! 2E
.
42
B
4F
O
62
B
6F
o
22
2F
/
43
C
50
P
63
C
70
p
23
#
30
0
44
D
51
Q
64
D
71
q
25
%
31
1
45
E
52
R
65
E
72
r
26
&
32
2
46
F
53
S
66
F
73
s
27
33
3
47
G
54
T
67
G
74
t
28
(
34
4
48
H
55
U
68
H
75
u
29
)
35
5
49
I
56
V
69
I
76
v
2A
Q
36
6
4A
J
57
W
6A
J
77
w
2B
+
37
7
4B
K
58
X
6B
K
78
x
2C
,
38
8
4C
L
59
Y
6C
L
79
y
39
9
4D
M
5A
Z
6D
M
7A
z
412-427 Custom Zone Descriptor 1
428-443 Custom Zone Descriptor 2
444-459 Custom Zone Descriptor 3
460-475 Custom Zone Descriptor 4
ADDRESS 476: ZONE EXPANDERS
476 Definition of Zone Expander Modules. When installing zone expanders (hardwire or
wireless), the system must be programmed to recognize the existence of the additional zones.
All defined zone expanders are supervised. If a zone expander is disconnected, all its zones
are opened. Note: Following any modifications made to this address, disconnect and
re-apply both AC and battery power to enable the changes to take effect.
Zone Expander
To install any combination of zone expander units enter the data value from the following table.
Second digit value
Units Value Units Value Units Value Units Value
A(1-8) 1 A,B 3 B,D A A,C,D D
B(9-16) 2 A,C 5 C,D C B,C,D E
C(17-24) 4 A,D 9 A,B,C 7 A,B,C,D F
D(25-32) 8 B,C 6 A,B,D B
Wireless Zone Expander
To add wireless zone expander units, enter a value from the following table. A wireless zone expander must
be defined in both the first and second digits of this address. For example, if three zone expanders ABC are
added to the control panel and B is wireless, the data entered at this address should be 27.
First digit value
W/L Units Value W/L Units Value W/L Units Value W/L Units Value
A(1-8) 1 A,B 3 B,D A A,C,D D
B(9-16) 2 A,C 5 C,D C B,C,D E
C(17-24) 4 A,D 9 A,B,C 7 A,B,C,D F
D(25-32) 8 B,C 6 A,B,D B
Seitenansicht 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 50 51

Kommentare zu diesen Handbüchern

Keine Kommentare