22
Latch Key
When the latch key feature is activated (address 411), the MENU/NEXT key is used to acknowledge arrivals or
departures from the system during opening or closing windows. If MENU/NEXT is not pressed after the user
code is entered, a ‘Failed to Open’ or ‘Failed to Close’ event code is sent to the central station.
Zone Chime
A zone can be programmed to chime when opened.
To program a zone to chime:
1. Press SELECT 3,3.
2. Enter an authorized user code.
3. Enter a zone number; the zone is programmed to chime when opened.
To deactivate a zone chime:
1. Press SELECT 3, 4.
2. Enter an authorized user code.
3. Enter the zone number; the zone will not chime when opened.
Access Control
This feature is designed for use with an electric door latch. The user is able to release the door latch from the
keypad by activating a relay programmed to “Access Control” mode – see address 477. A relay is controlled by
its corresponding keypad. For example, ‘Keypad 1’ controls ‘Relay 1’, ‘Keypad 2’ controls ‘Relay 2’ and so on.
Note: Keypad 8 cannot be used to operate this feature, as it has no relay assigned.
To activate an access control relay:
1. Press SELECT 9.
2. Enter an authorized user code; the relay is activated for the programmed cutoff time.
Set Relay
Relays can be manually activated and deactivated using this operation. A relay activated in this way is not
dependent on system status and stays activated until manually reset.
To manually activate a relay:
1. Press SELECT 8,4.
2. Enter the number of the relay you want to activate (1-7).
3. Enter an authorized user code; the relay is activated.
To manually reset a relay:
1. Press SELECT 8,3.
2. Enter the number of the relay you want to reset (1-7).
3. Enter an authorized user code; the relay is deactivated.